| Specifications |
727206 |
727207 |
727208 |
727209 |
727210 |
| Carbon Dioxide Sensor: Accuracy |
±0.025% CO2 |
±0.025% CO2 |
±0.025% CO2 |
±0.025% CO2 |
±0.025% CO2 |
| Carbon Dioxide Sensor: Drift |
Auto zero before each sample eliminates zero drift |
Auto zero before each sample eliminates zero drift |
Auto zero before each sample eliminates zero drift |
Auto zero before each sample eliminates zero drift |
Auto zero before each sample eliminates zero drift |
| Carbon Dioxide Sensor: Range |
0% to 2% CO2 |
0% to 2% CO2 |
0% to 2% CO2 |
0% to 2% CO2 |
0% to 2% CO2 |
| Carbon Dioxide Sensor: Repeatability |
±0.01% CO2 |
±0.01% CO2 |
±0.01% CO2 |
±0.01% CO2 |
±0.01% CO2 |
| Carbon Dioxide Sensor: Resolution |
0.001% CO2 |
0.001% CO2 |
0.001% CO2 |
0.001% CO2 |
0.001% CO2 |
| Carbon Dioxide Sensor: Response Time |
2.5 sec |
2.5 sec |
2.5 sec |
2.5 sec |
2.5 sec |
| Carbon Dioxide Sensor: Sample Flow Rate |
200 ml/min |
200 ml/min |
200 ml/min |
200 ml/min |
200 ml/min |
| Carbon Dioxide Sensor: Temperature Coefficient |
005%/degree C |
005%/degree C |
005%/degree C |
005%/degree C |
005%/degree C |
| Carbon Dioxide Sensor: Type |
Non-dispersive infrared NDIR |
Non-dispersive infrared NDIR |
Non-dispersive infrared NDIR |
Non-dispersive infrared NDIR |
Non-dispersive infrared NDIR |
| Dimensions: Cages |
Custom designed |
Custom designed |
Custom designed |
Custom designed |
Custom designed |
| Dimensions: Carbon Dioxide Analyzer, L x W x H English |
10.5 x 12 x 5.5 in |
10.5 x 12 x 5.5 in |
10.5 x 12 x 5.5 in |
10.5 x 12 x 5.5 in |
10.5 x 12 x 5.5 in |
| Dimensions: Carbon Dioxide Analyzer, L x W x H Metric |
26.67 x 30.48 x 13.97 cm |
26.67 x 30.48 x 13.97 cm |
26.67 x 30.48 x 13.97 cm |
26.67 x 30.48 x 13.97 cm |
26.67 x 30.48 x 13.97 cm |
| Dimensions: Flow Controller, L x W x H English |
(14.5 x 19.5 x 7 in |
(14.5 x 19.5 x 7 in |
(14.5 x 19.5 x 7 in |
(14.5 x 19.5 x 7 in |
(14.5 x 19.5 x 7 in |
| Dimensions: Flow Controller, L x W x H Metric |
36.83 x 49.53 x 17.78 cm |
36.83 x 49.53 x 17.78 cm |
36.83 x 49.53 x 17.78 cm |
36.83 x 49.53 x 17.78 cm |
36.83 x 49.53 x 17.78 cm |
| Dimensions: Oxygen Analyzer, L x W x H English |
10.5 x 12 x 5.5 in |
10.5 x 12 x 5.5 in |
10.5 x 12 x 5.5 in |
10.5 x 12 x 5.5 in |
10.5 x 12 x 5.5 in |
| Dimensions: Oxygen Analyzer, L x W x H Metric |
26.67 x 30.48 x 13.97 cm |
26.67 x 30.48 x 13.97 cm |
26.67 x 30.48 x 13.97 cm |
26.67 x 30.48 x 13.97 cm |
26.67 x 30.48 x 13.97 cm |
| Dimensions: Statistical Analyzer, L x W x H English |
10 x 10.75 x 4 in |
10 x 10.75 x 4 in |
10 x 10.75 x 4 in |
10 x 10.75 x 4 in |
10 x 10.75 x 4 in |
| Dimensions: Statistical Analyzer, L x W x H Metric |
25.4 x 27.31 x 10.16 cm |
25.4 x 27.31 x 10.16 cm |
25.4 x 27.31 x 10.16 cm |
25.4 x 27.31 x 10.16 cm |
25.4 x 27.31 x 10.16 cm |
| Flow Pumps Vacuum |
Capacity 5 SLPM/20 SLPM |
Capacity 5 SLPM/20 SLPM |
Capacity 5 SLPM/20 SLPM |
Capacity 5 SLPM/20 SLPM |
Capacity 5 SLPM/20 SLPM |
| Humidity |
0% to 90% relative humidity non-condensing |
0% to 90% relative humidity non-condensing |
0% to 90% relative humidity non-condensing |
0% to 90% relative humidity non-condensing |
0% to 90% relative humidity non-condensing |
| Mass Flow Meter: Accuracy |
neg 0.01 SLPM |
neg 0.01 SLPM |
neg 0.01 SLPM |
neg 0.01 SLPM |
neg 0.01 SLPM |
| Mass Flow Meter: Repeatability |
neg 0.02 SLPM |
neg 0.02 SLPM |
neg 0.02 SLPM |
neg 0.02 SLPM |
neg 0.02 SLPM |
| Mass Flow Meter: Resolution |
0.001 SLPM |
0.001 SLPM |
0.001 SLPM |
0.001 SLPM |
0.001 SLPM |
| Mass Flow Meter: Thermal Range |
0 to 5 SLPM/0 to 20 SLPM |
0 to 5 SLPM/0 to 20 SLPM |
0 to 5 SLPM/0 to 20 SLPM |
0 to 5 SLPM/0 to 20 SLPM |
0 to 5 SLPM/0 to 20 SLPM |
| Oxygen Sensor: Accuracy |
±0.005% O2 |
±0.005% O2 |
±0.005% O2 |
±0.005% O2 |
±0.005% O2 |
| Oxygen Sensor: Drift |
0.005% O2 over 24 hours |
0.005% O2 over 24 hours |
0.005% O2 over 24 hours |
0.005% O2 over 24 hours |
0.005% O2 over 24 hours |
| Oxygen Sensor: Humidity |
0% to 90% Relative humidity non condensing |
0% to 90% Relative humidity non condensing |
0% to 90% Relative humidity non condensing |
0% to 90% Relative humidity non condensing |
0% to 90% Relative humidity non condensing |
| Oxygen Sensor: Pressure Coefficient |
Negligible |
Negligible |
Negligible |
Negligible |
Negligible |
| Oxygen Sensor: Range |
18% to 22% O2 standard (0% to 100% O2 available by special order) |
18% to 22% O2 standard (0% to 100% O2 available by special order) |
18% to 22% O2 standard (0% to 100% O2 available by special order) |
18% to 22% O2 standard (0% to 100% O2 available by special order) |
18% to 22% O2 standard (0% to 100% O2 available by special order) |
| Oxygen Sensor: Repeatability |
±0.005% O2 |
±0.005% O2 |
±0.005% O2 |
±0.005% O2 |
±0.005% O2 |
| Oxygen Sensor: Resolution |
0.001% O2 |
0.001% O2 |
0.001% O2 |
0.001% O2 |
0.001% O2 |
| Oxygen Sensor: Response Time |
0.3 seconds |
0.3 seconds |
0.3 seconds |
0.3 seconds |
0.3 seconds |
| Oxygen Sensor: Sample Flow Rate |
200 ml/Min |
200 ml/Min |
200 ml/Min |
200 ml/Min |
200 ml/Min |
| Oxygen Sensor: Temperature Coefficient |
Negligible |
Negligible |
Negligible |
Negligible |
Negligible |
| Oxygen Sensor: Type |
Zirconia |
Zirconia |
Zirconia |
Zirconia |
Zirconia |
| Parameters Measured |
The following parameters are measured in the standard model: Oxygen consumption (mL/kg/hr), carbon dioxide production (mL/kg/hr), respiratory exchange ratio (CO2/VO2) and heat Kcal/hr) |
The following parameters are measured in the standard model: Oxygen consumption (mL/kg/hr), carbon dioxide production (mL/kg/hr), respiratory exchange ratio (CO2/VO2) and heat Kcal/hr) |
The following parameters are measured in the standard model: Oxygen consumption (mL/kg/hr), carbon dioxide production (mL/kg/hr), respiratory exchange ratio (CO2/VO2) and heat Kcal/hr) |
The following parameters are measured in the standard model: Oxygen consumption (mL/kg/hr), carbon dioxide production (mL/kg/hr), respiratory exchange ratio (CO2/VO2) and heat Kcal/hr) |
The following parameters are measured in the standard model: Oxygen consumption (mL/kg/hr), carbon dioxide production (mL/kg/hr), respiratory exchange ratio (CO2/VO2) and heat Kcal/hr) |
| Response Time |
0.25 seconds |
0.25 seconds |
0.25 seconds |
0.25 seconds |
0.25 seconds |
| Temperature and Pressure |
Effects are eliminated by sensor design and computer compensation |
Effects are eliminated by sensor design and computer compensation |
Effects are eliminated by sensor design and computer compensation |
Effects are eliminated by sensor design and computer compensation |
Effects are eliminated by sensor design and computer compensation |
| Weight (Drierite Columns) English |
2.5 lbs |
2.5 lbs |
2.5 lbs |
2.5 lbs |
2.5 lbs |
| Weight (Drierite Columns) Metric |
1.13 kg |
1.13 kg |
1.13 kg |
1.13 kg |
1.13 kg |
| Weight (all analyzers) English |
12 lbs |
12 lbs |
12 lbs |
12 lbs |
12 lbs |
| Weight (all analyzers) Metric |
5.44 kg |
5.44 kg |
5.44 kg |
5.44 kg |
5.44 kg |
| Weight (cages) English |
6 lbs |
6 lbs |
6 lbs |
6 lbs |
6 lbs |
| Weight (cages) Metric |
2.72 kg |
2.72 kg |
2.72 kg |
2.72 kg |
2.72 kg |
| Weight (flow controller) English |
39 lbs |
39 lbs |
39 lbs |
39 lbs |
39 lbs |
| Weight (flow controller) Metric |
17.69 kg |
17.69 kg |
17.69 kg |
17.69 kg |
17.69 kg |